We offer a range of accessories designed to work with our range of Architectural Louvres.
GUARDS & MESHES
BLANKING PANELS
LOUVRED DOORS
DAMPERS

GUARDS & MESHES

Some protection against birds or vermin is often required with louvre installations. Insect meshes can also be specified.

Guards / meshes are usually permanently fixed to the back of louvre modules, but if required can be supplied with frames to allow for their easy removal for maintenance.

Consideration needs to be given to the impact of these accessories on airflow and, particularly when using insect mesh, ensuring easy access to louvred areas for regular maintenance.

* Our louvres are tested without any guards attached. The % reduction values are indicative of airflow performance reduction and may vary per louvre model. The values apply to new installations, or ones that had been cleaned and maintained regularly.

BIRD / VERMIN GUARDS

Galvanised welded mesh (standard)
  • Material: Galvanised steel (stainless steel option available)
  • Wire diameter: 1.5 mm
  • Aperture: 12.7 mm x 12.7 mm
  • Finish: Unfinished as standard
  • Weight: 0.37 kg/m2
  • Open area: 76%
  • Louvre airflow reduction*: up to 5%
  • Stock size: 1220 mm wide x 30 m long roll
Expanded aluminium (optional)
  • Material: Aluminium alloy 1050 H14
  • Material thickness: 1.14 mm
  • Aperture: 33.53 mm x 12.45 mm
  • Finish: Mill finished as standard, or can be powder coated in RAL colours
  • Weight: 0.87 kg/m2
  • Open area: 73%
  • Louvre airflow reduction*: up to 10%
  • Stock size: 1250 mm wide x 3000 m high sheet

INSECT MESH

  • Material: PVC coated fibreglass (stainless steel option available)
  • Wire diameter: 0.22 mm
  • Aperture: 1.18 mm x 1.36 mm
  • Finish: Black
  • Weight: 0.11 kg/m2
  • Open area: 72%
  • Louvre airflow reduction*: up to 12%
  • Stock size: 1200 mm wide x 30 m long roll

BLANKING PANELS

Non-active areas of a louvred façade can have single skin blanking plates or insulated panels fitted behind the louvres.

SINGLE SKIN ALUMINIUM PLATES

Material

  • 2 mm thick aluminium as standard.

Sizes

  • Supplied in sizes to best suit project requirements. Can be pre-fitted to louvre modules if required.

Finishes

  • Standard – mill finished aluminium
  • Polyester powder coated or anodised to match louvre finish on request
INSULATED PANELS

Materials

  • Insulated panels comprise thermal insulation core material faced on both sides with a 1 mm thick aluminium sheet and set within an aluminium channel frame.

Insulation material options include:

  • Non-combustible, A1 classified (to EN 13501-1) high strength stone wool core faced with open filament net
  • Extruded polystyrene core

Panel thickness will vary, depending on the chosen core type and project’s insulation requirements.

Sizes

  • Supplied in sizes to match louvre sizes. Can be pre-fitted to modules if required.

Finishes

  • Mill finished
  • Polyester powder coated or anodised to match louvre finish

LOUVRED DOORS

Where louvred doors are required to gain access into areas such as plant rooms, we offer solutions to suit most needs.

Example: doors featuring RSH-5700 blades

KEY FEATURES:

  • Manufactured to bespoke sizes and specifications
  • Maximum size of a single door leaf is 2400 mm x 1150 mm (may vary per model type)
  • Single and double door configurations are available
  • Door leaf frames filled with louvre blades to match the rest of the louvred façade
  • Typically supplied with a door frame and pre-fitted hinges
  • Other hardware, including locks, door closers etc. can be supplied

DAMPERS

Where required, we can offer a selection of volume control dampers for installation with louvre solutions.

Motorised or manually operated options in uPVC or aluminium are available to meet performance and budget requirements.

HIGH PERFORMANCE uPVC VOLUME CONTROL DAMPERS
  • For areas where low leakage insulated solution is required
  • Manufactured mainly from uPVC to reduce heat loss through conduction and condensation
  • Corrosion resistant design
  • Low U value of 1.2 W/m2K
  • Drive system enclosed within the frame, for reliable long term performance and low maintenance
  • Tested for air leakage (up to 2000 Pa static pressure). Low and high pressure specifications available.
  • Tested to EN ISO 10140-2:2010 for acoustic performance
  • Choice of actuators types
ALUMINIUM VOLUME CONTROL DAMPERS
  • General purpose volume control damper
  • Lightweight aluminium construction
  • High resistance to corrosion
  • Fully protected low torque drive system for easy operation from a single manual handle or actuator
  • Additional blade edge and frame side seals for reduced air leakage if required
  • Opposed blade motion as standard, parallel motion on request (see sectional details)
  • Control options for manual and motorised operation

Spécificités

Guidance

The principal reason for using louvres is to allow the movement of air. But, louvre specification is a balance between form and function, with louvred façade appearance playing an important part in the selection process.

  • Performance Considerations
  • Design Considerations
  • Weather Louvre Testing
Learn more

Grilles de ventilation

2016 Louvre Brochure
Dans la brochure :
  • - Produits leaders du secteur
  • - Nouvelles options de design innovantes
  • - Informations techniques détaillées
  • - Guide de sélection des grilles de ventilation

+33 (0)2 32 67 00 00
information@c-sgroup.com
Commander un échantillon
Demander un devis
Obtenir une aide technique

Menu

  • Produits CS
  • réalisations
  • CONSEILS & ACTUS
  • Qui sommes-nous ?
  • Contact
  • Changer de pays

Contact

CS France
135, rue Edouard Isambard
B.P. 66
27120 Pacy-sur-Eure Cedex
FRANCE
Venir nous voir
Tel: +33 (0)2 32 67 00 00
Fax: +33 (0)2 32 67 14 12
Email: information@c-sgroup.com

Confidentialité

Pour vos offrir la meilleure expérience possible lors de votre visite, ce site web utilise des cookies. En continuant sur ce site, vous accepter d'utiliser ces cookies. Pour en savoir plus sur la façon dont nous utilisons et les cookies et comment les gérer, consultez notre politique de confidentialité ci-dessous.
Politique de confidentialité

Copyright © 2025 · Construction Specialties

Copyright © 2025 · Genesis Framework · WordPress · Log in